Welcome to Acta Armamentarii ! Today is

Acta Armamentarii ›› 2017, Vol. 38 ›› Issue (2): 367-373.doi: 10.3969/j.issn.1000-1093.2017.02.022

• Paper • Previous Articles     Next Articles

Analysis and Correction of Installation Errors of Laser Parallel Detector Array Barrage Measuring System

XU Da1, HE Kai-ping1,2, LUO Jian-hua1, LI Hua1   

  1. (1.Department of Arms Engineering, Academy of Armored Force Engineering, Beijing 100072, China; 2.Unit 65334 of PLA, Yanji 133000, Jilin, China)
  • Received:2016-06-22 Revised:2016-06-22 Online:2017-04-01

Abstract: A line laser parallel detector array barrage weapon dispersion measuring method is presented for structure installation errors.The influences of installation errors on measurement are researched, and an error transfer formula is given. The measuring error distribution of structural installation errors is analyzed quantitatively. When a target area is 10 m×10 m, the installing distance error σ of detector array and line laser is 5 cm, and the target leans 2° to the right and 2° backwards. The results show that the maximum error of x coordinate is -10.87 cm, the maximum error of y coordinate is 2.13 cm. Measurement experiment of the coordinate is carried out in the case of installation error according to the distribution of measurement errors, and the coordinate measurement errors are corrected according to the experimental data. Key

Key words: ordnancescienceandtechnology, photoelectricmeasurement, erroranalysis, linelaserdetectorarray, installationerror, dispersionmeasuring

CLC Number: